Platform
One pipeline from first packet to audit proof.
Synaptic OT is a single on-premises platform. Every packet, vendor alert and project file travels the same path, so detection, forensics, response and compliance always agree on the facts.
Attacks have reached the process.
Adversaries now write directly to controllers over plain industrial protocols. Regulators have responded by asking for proof, not intentions: logs, evidence and audit trails that most mid-size plants don't have.
- NESA / UAE IA
- NCA OTCC
- CERT-In
- NIS2
- IEC 62443
- NERC CIP
- 2023
Internet-exposed Unitronics PLCs taken over at US water utilities
CISA advisory AA23-335A - 2024
FrostyGoop malware uses Modbus TCP to cut heating to buildings in Lviv, Ukraine
Disclosed July 2024 - 2024
US agencies warn Volt Typhoon has pre-positioned inside critical infrastructure
CISA advisory AA24-038A
How it works
Seven stages, one record.
Each stage is deterministic and logged. The same data that triggers an alert is the data that ends up in the evidence pack.
- 01
Sources
SPAN or TAP on the OT network, uploaded PCAPs, engineering project files, Nozomi and Claroty alerts, Splunk, syslog and SNMP traps.
- 02
Dissect
Protocol decoders for six OT protocols turn traffic into a common event model. Project files become an engineering model of assets, connections and tags.
- 03
Enrich
Asset lookup, baseline context, tag names from your projects and vulnerability matches. Credentials in payloads are stripped before anything else sees them.
- 04
Detect
35 active OT detection rules mapped to MITRE ATT&CK for ICS, anomaly detection, protocol-compliance checks and CyOTE-based correlation run independently. None depends on AI.
- 05
Record
The Wire DVR keeps rolling capture, locks the window around each incident and indexes every packet for search and retro-hunt.
- 06
Respond
Critical alerts become incidents and match playbooks. Every action waits for a person, with blast radius and exact rule text.
- 07
Prove
Approvals, notes and evidence land in an HMAC-chained audit log and roll up into per-framework evidence packs.
Inputs
Protocols on the wire
- Modbus TCPIncluding Schneider UMAS
- DNP3Utility SCADA and electric grids
- Siemens S7commSiemens S7 PLC engineering and control
- EtherNet/IP / CIPRockwell and Allen-Bradley lines
- BACnet/IPBuilding automation, HVAC, access
- IEC 60870-5-104Telecontrol for power transmission
Inputs
Engineering project files
Read from the open exports your engineers already produce. Each file is stamped with an honest fidelity level.
- Rockwell L5X
- Rockwell ACD
- Schneider XEF
- Schneider ZEF
- PLCopen XML
- EtherNet/IP EDS
- AutomationML
- CSV tag databases
Engineering file import also reads these files to build the asset and engineering model. The protocols they describe are not monitored on the wire.
- IEC 61850 SCL (.scd) substation configuration
- PROFINET GSDML device descriptions
AI, used carefully
The assistant explains. The rules decide.
Detection in Synaptic OT is deterministic. The same traffic always produces the same alert, which is what an auditor, a safety engineer and a court expect.
An AI assistant then writes plain-language alert explanations, incident summaries and tuning suggestions for your analysts. It runs inside your deployment, including fully air-gapped sites, and its output never reaches the detection pipeline. It cannot suppress an alert or change a severity, and if it is unavailable, analysts get template explanations while detection carries on.
New detection rules suggested by the assistant go through validation, replay against recorded traffic and human approval before they are promoted.
Workspaces
A view for everyone who touches an incident.
Role-based workspaces with SSO (SAML or OIDC) and TOTP multi-factor authentication. The interface is available in eleven languages, including Arabic with right-to-left layout.
SOC analyst
Alert queue, triage and investigation, retro-hunt, remediation cards.
OT engineer
Asset register, project baselines, maintenance windows, protocol decoder.
Shift manager
Playbook step approvals, incident oversight and remediation decisions.
CISO and executives
Compliance scorecards per framework, auditor evidence packs and incident overview.
Compliance lead
Control scorecards, attestations, auditor evidence packs.
MSSP partner
Multi-tenant console, client consent, branding and usage metering, for partners who operate the platform.
Deployment
Four tiers, one product.
Full air gap, semi air gap, hybrid multi-site and MSSP. The difference between them is configuration, not a different edition.
Deployment tiers →Trust
Built like it will be audited.
Signed offline installer, generated secrets with no defaults, deny-by-default egress, published SBOMs and zero copyleft in the shipped runtime.
Trust & security →See it live, then on your own traffic.
Book a demo with an engineer who built it. When you are ready, request an evaluation licence and run Synaptic OT on a mirror port or a PCAP from your plant, fully offline if you need it to be.